The Single Best Strategy To Use For Dp50rb

one.two.two Warning Labels Warning Labels That means Please meticulously look at this handbook just before use system. The next labels really are a. Never area the gadget with a sloped floor. Or else the obtainable when the procedure system could slide, causing particular injuries or the system operates with the cellular malfunction.

iZoom™ allows exact viewing of picture from length iWorks™ Protocol can help standardize workflow and minimize exam situations

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi depth mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Notice: Guantee that you can pull out and drive in the IO board sockets vertically when pulling out and assembling the IO board assembly over the situation with the take care of. Take out panhead screws with washers M3X6 (four) used to protected the IO board, and then you can just take out the IO board. Web page 116 Remove panhead screws with washers (2 M3X6) that are preset on the primary unit, consider out the upper baffle and then pull out two cables connecting the leading board to the power module assembly.

The chapter materials the method to verify main purpose and performance of products. This really is only employed for reference, not preventive execution. Operate examining and screening of the element shall be performed by Mindray provider engineers as well as the user together. Web site sixty six: Basic Examination

Purpose: About the again-finish of the leading board, a Exclusive keep track of IC is applied to watch signal voltages  and clock battery electricity that are supplied to the principle board by the most crucial device box power offer module.

Functionality Check 5.five.1 Test Process Resolution Detection depth Geometric Situation Accuracy Blackout place examination Record the Examination images five.five.two Check Content The picture used here is only for reference, keep on with the image influence in the true Observe: scenario. Specifications: Display screen: set the contrast and brightness on the scientific software value (or the default position) Procedure surroundings: dark area, simulating the medical software natural environment. Page 76 In condition the transverse resolution testing targets are horizontally shown, history the negligible distance of two targets which might be clearly recognized. Repeat the operation earlier mentioned for the transverse resolution screening targets at other depths. As demonstrated in figure under. Axial resolution ... Webpage 77 When using the convex probe, hold the transverse resolution testing targets to NOTE: be displayed near the midline. When using a linear probe with steer functionality, usually do not turn on the steer purpose when perform the transverse resolution check. Zoom during the area where by the targets Found if important. The diameter from the target stage at a certain depth is equal on the transverse resolution on the depth. Website page 78 five.

By continuing your check out on our Web-site, you might be consenting to our usage of cookies. Nevertheless, you may alter your cookie settings Anytime.  Cookie preference Accept and Commence

Highest 4 occasions tasking for one transmitted beam, leading to excellent time resolution and higher body amount.

Aid 4D probe; figure out the probe by means of the ID code; switch the 4D travel signal via the  electrical relay to make the 4D probe do the job Commonly. 4.2.two Primary board The main board can be divided into two areas: entrance-stop of the primary board Dp50rb login and again-conclude of the key board.

Any time you prevent the scanning and the graphic seize, it is best to ability off the program and disconnect the program from your AC electrical power supply, then pull out AC power cables. Web site 109: Battery Connecting Board

Get a complete and prolonged perspective of your anatomical composition as a result of panoramic imaging coupled with velocity indicator and forward/backward scan capacity producing scanning less difficult, smoother and a lot more controllable.

A smart new form, Improved mobility and hassle-free Procedure make DP-50 well matched for all scientific options.

Content Approach Test the battery periodically : a) Check if battery is often charged normally when energy-on: That The existing potential is 100% or capacity increases immediately after a brief time implies which the battery is often charged Commonly.

Leave a Reply

Your email address will not be published. Required fields are marked *